DFIT advisory

DFIT and mini-frac advisory

A diagnostic fracture injection test is a small, cheap test that can save or waste a lot of money. Run well, it gives you closure stress, an estimate of reservoir pressure and permeability, and a basis for frac design or caprock integrity work. Run poorly, with too much volume, the wrong gauge or a shut-in cut short, it gives you a falloff nobody can pick closure from.

Request a program review
DFIT · FALLOFFILLUSTRATIVE
IllustrativeShut-in timePressureinjectionISIPclosureafter-closurereservoir pressure (est.)

We work on the operator's side: designing the DFIT or mini-frac test, making sure it is executed to plan, and delivering data that holds up to DFIT analysis.

DFIT vs mini-frac

DFIT vs mini-frac

The terms get used loosely. In this site's usage:

  • A DFIT is a small-volume, low-rate injection followed by a long shut-in, designed mainly to read closure and reservoir properties from the pressure falloff.
  • A mini-frac test (mini frac, or data frac) is usually larger, often uses frac fluid, and is aimed at calibrating the main fracture treatment: fluid efficiency, leak-off and net pressure.

Which one you need depends on what decision the data feeds. We'll help you pick and size it.

Design

Design

  • Objective. Closure stress, pore pressure, permeability, leak-off, caprock integrity or frac calibration. Pick the main one and design for it.
  • Injection volume and rate. Enough to break down and propagate a fracture past the near-wellbore, small enough not to stretch out the falloff unnecessarily.
  • Fluid. Water, brine or treatment fluid, chosen for compatibility and for what you want to measure.
  • Gauges. Resolution, range and sample rate suitable for a slow, low-amplitude falloff. Surface vs downhole placement, and what that means for the data.
  • Shut-in duration. Long enough to get past closure and, if permeability is an objective, into after-closure flow. In tight rock that can mean days or weeks, and the program should say so plainly.
  • Isolation and wellbore integrity. Making sure the pressure you record is the formation's, not a leak.
Execution oversight

Execution oversight

On location or remotely, we check that the pumping schedule, gauge installation and shut-in are run as designed. That means confirming gauge calibration and clocks, watching breakdown and injection pressures, recording any upsets, and keeping the well shut in for the full planned time.

Data and analysis

Data and analysis

At the end of the test we QC the pressure record and flag anything that affects interpretation: temperature effects, leaks, gauge drift and pumping irregularities. We then do the DFIT analysis, including G-function, log-log diagnostics and after-closure analysis, and report closure pressure, an estimate of reservoir pressure and permeability where the data supports it, and what the results mean for your frac design or injection limits.

Where DFITs are used

Where DFITs are used

  • Unconventional completions: frac design and stress profiling
  • Disposal and CO2 injection wells: fracture pressure and safe injection limits
  • Carbon storage: caprock and reservoir characterization
  • Geothermal: stimulation planning and injectivity
  • Regulatory tests where a DFIT or mini-frac is required
Request a program review

Request a program review

Send us the well, the zone and what the DFIT or mini-frac needs to answer.

Request a program review