Test data review, PTA and reporting
At the end of a test you usually have gauge files, a vendor report, daily sheets, lab results and a lot of emails. What you need is a short, honest answer: what did the test show, how confident should we be, and what do we do next. That's the purpose of a data package.
Request a program reviewData QC
Before anyone interprets a test, the data has to be checked:
- Gauge files reconciled against the sequence of events: opens, closes, choke changes, upsets
- Clock and depth corrections, gauge-to-gauge comparison and drift checks
- Surface rates and volumes reconciled with tank straps, meters and the separator record
- Sample chain of custody and lab results checked against the sampling conditions
- Gaps, noise and anomalies identified and explained, not smoothed over
Results summary
A plain-language summary written for the engineers, geologists and managers who have to act on the test:
- Objectives, and whether each one was met
- Key results: rates, pressures, fluid, and preliminary reservoir parameters where the data supports them
- What the data can't tell you, and why
- Recommendations: development decision inputs, retest needs, or changes to the next program
Well test analysis and interpretation
Pressure transient analysis is where the reservoir parameters come from: permeability, skin, reservoir pressure, boundaries and, for gas wells, deliverability from the deliverability test or AOF data. We do the pressure transient analysis and well test interpretation on the QC'd dataset, with the event log and rate history tied in, and report the results with the assumptions and uncertainty stated plainly. DFIT interpretation is covered on the same basis (see DFIT and mini-frac advisory).
For injection, salt water disposal and CO2 storage wells, the package covers injection test, falloff and step-rate results and the fracture-pressure evidence that supports injection limits.
Regulatory submissions
Test results often have to go to the regulator in a set format. We assemble the test data and summaries the submission needs.
Second look at an old test
If you have a past test that didn't give a clear answer, we can review the data and tell you whether it's usable, what it does show, and what a retest would need to do differently.
What you get
- QC'd data files with an event log
- A short written report: objectives, results, limits, recommendations
- Pressure transient analysis and/or DFIT interpretation
- A review call with your team
Request a program review
Send us the test data or the report you're trying to make sense of.
Request a program review